Power-failure and phase-loss alarm beacon: internal battery, flashing red lens

Baomingxiang power-failure and phase-loss beacon: alarms on a lost phase, flashes at high brightness with a loud horn, and keeps working on an internal battery that charges automatically. Bolted base with terminals underneath, wired to a controller's alarm output for livestock houses and distribution boards.

TriggersPower loss / lost phase
SignalFlashing lens + loud horn
BackupInternal battery, self-charging
MountingBolted base, bottom terminals
ForLivestock houses, distribution boards
Taobaohttps://item.taobao.com/item.htm?id=782750582767
Our stores
Price and stock follow the store listings; bank transfer supported. For a configuration or an invoice, use the consultation on the right.

Red lens, off-white base, a label reading "extra-loud sound-and-light power failure alarm", and three threaded terminals emerging from the bottom. It measures no temperature and drives no fan; it does one thing — makes sure somebody knows when something goes wrong. Power loss or a lost phase, and it flashes and sounds.

Four claims, really two jobs

The four lines on the image are phase-loss alarm, high-brightness flashing, internal battery, automatic charging. The first two make it seen and heard; the last two make it work when the power is not there. Both halves are needed — light without sound is invisible to whoever is working in the house by day, and sound without light leaves the night watch guessing which unit it is.

A lost phase is what three-phase motors fear most

On a three-phase 380 V fan or pump, one conductor can drop and the motor may keep turning — with the wrong current, insufficient torque and winding temperature climbing. Standing next to it, nothing sounds unusual; by the time there is a smell of scorching or a breaker trips, the winding is already burnt. Phase-loss alarm buys the interval before that: one phase goes, the lamp flashes and the horn sounds, in time to cut the supply.

Internal battery plus automatic charging is what makes it a power-failure alarm

An alarm lamp without a battery goes dark at exactly the moment the power does, which is no power-failure alarm at all. This one carries a battery, charges it while mains power is present, and switches to it when the supply drops. A power failure on a farm is not a small event: fans stop, pads run dry, and half an hour in summer can push a house up while winter brings a different kind of stillness. The value is that the alarm is still working at the moment the power is not.

Where it goes

Three usual positions: on the side of a control cabinet, wired to the controller's alarm output; beside a distribution board, where phase loss and outages actually occur; and at the end of an internal walkway, where anyone in the house can see and hear it. The base bolts to a wall or an enclosure, terminals taken from below. Higher is better than lower — on a night round the red light carries.

Wiring and selection

Three things to settle first: supply voltage (220 V or 380 V on your site), how many phases to monitor (power loss only, or phase loss on a three-phase supply as well), and inside or outside the cabinet. There is no single universal version, and the wrong one will not fit, so state all three when ordering. Phone: +86 199 3789 6911.

Working with a temperature cabinet

The cabinet does the controlling — starting fans on temperature, trimming speed. The alarm does the reporting, turning temperature and supply problems into light and sound. Paired, the cabinet's dry alarm contact goes to the beacon, so the over-temperature, under-temperature and power-failure settings inside the cabinet all gain a visible and audible signal. For a complete set, send the house type, fan count and channel count and we will return a list.

Send us your site details, get a configuration the same day

Just three numbers: what you raise, how many, and how many houses. We work out outputs and fan count.

微信二维码 Scan on WeChat · send your house type
Or call 199 3789 6911

Questions about sizing? Leave a note

T P D