Staff training in temperature control knowledge

2026.11.18 ·Zhengzhou, Henan, China

After its kick-off meeting Baomingxiang ran a practical session on temperature control: reading temperature curves, setting hysteresis, probe placement, the order of checks for over-temperature, low temperature and power alarms, and how fan speed relates to negative pressure.

Staff training in temperature control knowledge

The goals were set; nobody left the room

The kick-off meeting put the year's targets on the table, the banner went up, thumbs went up, the group photo was taken — and the meeting did not end there. Workshop, sales and service staff sat back down and went through temperature control from the beginning. Equipment is inanimate; the people who install it, tune it and explain it to customers are not.

Baomingxiang staff in a temperature control knowledge session after the kick-off meeting

First, learning to read temperature

The same house needs different temperatures at brooding, growing and finishing. Behind that curve on the screen are age in days, body weight, feed intake and the weather that day. The point is that when you see 27.8°C you can judge whether it warrants an alarm, rather than simply reading out a number.

Then there is hysteresis. With a setpoint of 28°C and a 1°C differential, the equipment does not need to cycle while temperature moves between 27 and 29. Too narrow and fans and heaters switch dozens of times a day; too wide and the house cannot hold its temperature band.

Next, where the probe goes

A probe in the wrong place makes everything downstream wrong: in front of a fan it reads air velocity, not house temperature; by the door it jumps whenever the door opens; behind a feed line or drinker it measures a corner; mounted too high it misses the real temperature at pig height. With the wrong position, even correct control logic fails.

So this session used real hardware: how to fix the probe, how to route the cable, how to seal the connector, and what to suspect first when the reading jumps. Farm houses are humid, and oxidised terminals and water ingress are the most common sources of false alarms — something only people who have been on site can explain properly.

When an alarm sounds, what comes first

Over-temperature, low temperature and power failure each call for a different order of checks. For a power alarm, confirm first whether the whole farm is out or one house tripped. For over-temperature, check whether fans are running and inlets are open. For low temperature, rule out a faulty probe before changing any setpoint. Knowing that order is what keeps a midnight call from turning into panic.

We also covered the link between fan speed and negative pressure: raising speed changes house pressure, and inlet opening has to follow — otherwise airflow does not increase and the fan is simply working against a closed house.

Why sales staff need this too

When a customer calls, the first question is rarely "how much" — it is usually "this house keeps overheating, what should I do". Without an answer you are just a price list; being able to ask how many houses, how many fans, where the probes sit is what qualifies you to discuss a solution.

This was not a one-off lecture: site Q&A and installation reviews follow. Whether it has been learned shows the moment you stand in a customer's house.

Back to the same point

Learning the technical side properly comes down to making farms easier to run: one false alarm fewer means one trip to the house fewer; a more accurate configuration means one less rewiring job. That is the sentence we keep coming back to — making livestock farming easier.

For temperature control, ventilation or alarm questions, contact us on +86 199 3789 6911.

Send us your site details, get a configuration the same day

Just three numbers: what you raise, how many, and how many houses. We work out outputs and fan count.

微信二维码 Scan on WeChat · send your house type
Or call 199 3789 6911

Questions about sizing? Leave a note

T P D